ZSE30/ISE30 High Precision,
2-color Display Digital Pressure Switch Series
Pressure setting
Manual setting
Press the SET button in the measuring mode to display the
set value. and the current set value blink alternately.
PRESSURE
OUT
Normally Open
PRESSURE
Alternately
displayed
PRESSURE
OUT
OUT
Normally Closed
Press the SET button to display the next set value. Press the
̅UP or ̃DOWN button to change the value. (Refer to “How
to Set Value” on the lower right hand corner of this page.)
Hysteresis mode
In this mode, hysteresis (H) and the set value for hysteresis
are displayed alternately after setting P1. Press the SET
button to return to the normal measuring mode. Press the
̅UP or ̃DOWN button to change the value.
(Refer to “How to Set Value” below right.)
Window comparator mode
In this mode, P2 and the current set value are displayed
alternately after setting P1. Press the SET button to display
the next set value ( : hysteresis). Press the ̅UP or ̃DOWN
button to change the value.
(Refer to “How to Set Value” at right.)
Next, and the set value for hysteresis will be displayed
alternately. Press the SET button to return to the normal
measuring mode. Press the ̅UP or ̃DOWN button to
change the value.
(Refer to “How to Set Value” at right.)
Pressure set value can be verified without holding or stopping
the switch output operation.
Auto preset setting
1. Auto preset preparation mode
While in the measuring mode, press the SET button to
activate the auto preset preparation mode, and
will be
displayed. Proceed to prepare the devices to perform the
pressure setting. While is still displayed, press both the
̅UP and ̃DOWN buttons simultaneously to return to the
measuring mode.
PRESSURE
ZSE„
ISE„
PSE
ZI SE3
OUT
PS
2. Auto preset setting
Press the SET button to activate the mode to execute auto
preset functions. When
is displayed, start the system
operation and change the pressure. The set value will be
automatically detected and stored.
While is still displayed, press the SET button to complete
the setting and return to the normal measuring mode.
PRESSURE
ZI SE12
ZSP
ISA2
IS„
ZSM
OUT
PF2„
How to Set Value
To enter a value such as the one for pressure setting:
1. Press the ̅UP or ̃DOWN button to change the set
value. The first digit blinks.
IF„
Data
1st digit
2. Press the ̅UP or ̃DOWN button to set the value
arbitrarily. (If there is no button operation for more than
10 seconds, the current value will be automatically set
and the function will return to the set value display
mode.)
3. With every push of the SET button, the next (higher)
digit blinks.
2nd digit
3rd digit
When the left-most digit is zero, “ ” or “ ” will blink.
If the SET button is pressed while the left-most digit is
blinking, the right-most digit will now blink.
4. Press and hold the SET button for 1 second or longer
to return to the set value display mode.