English
Language : 

MC3433 Datasheet, PDF (30/45 Pages) List of Unclassifed Manufacturers – Axis Accelerometer
MC3433 3-Axis Accelerometer
Preliminary Datasheet
11.3 SR STATUS REGISTER
This register contains the flag/event bit for sample acquisition.
The flag (and interrupt) is cleared and rearmed each time this register is read.
Addr Name Description
Bit 7 Bit 6
Bit 5 Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
POR R/
Value W
0x03 SR Status Register ACQ_INT Resv Resv Resv Resv Resv Resv Resv 0x00 R
ACQ_INT
0: No sample has been generated by the sensor since last read.
1: Sample has been acquired, flag bit is set in polling mode or interrupt mode. This bit
cannot be disabled and is always set be hardware when a sample is ready. The host
must poll at the sample rate or faster to see this bit transition.
Table 14. SR Status Register
mCube Proprietary.
APS-048-0025v1.7
© 2014 mCube Inc. All rights reserved.
30 / 45