SPECIFICATIONS: (Measurements @ 25C, unless otherwise noted; VDA = VDD= 1.8V unless otherwise specified)
Parameter
Conditions
Field Range
(Each Axis)
Supply Voltage
Supply Current2
Power Down Current
Operating Temperature
Storage Temperature
Linearity Error
(Best fit straight line)
Hysteresis
Repeatability Error
Alignment Error
Transverse Sensitivity
Total RMS Noise
Output resolution
Heading accuracy3
Bandwidth
Sensitivity
Sensitivity Change Over
Temperature
Null Field Output
Total applied field
VDA
VDD (I2C interface)
7 measurements/second
±16 gauss
3 sweeps across ±16 gauss
3 sweeps across ±16 gauss
1~25Hz, RMS
16 gauss
16 gauss
-40~85C
16 gauss
16 gauss
Null Field Output Change Over
Temperature 4
Disturbing Field
Maximum Exposed Field
Delta from 25C
16 gauss
Min
1.621
1.621
0.06
0.01
-40
-55
-10
460
-0.2
8090
25
Typ
16
1.8
1.8
0.10
1.0
0.5
0.5
1.0
2.0
2.0
14
0.5
25
512
1100
8192
0.4
Max
Units
gauss
3.6
V
3.6
V
0.16
mA
1.0
µA
85
C
125
C
%FS
%FS
%FS
3.0
degrees
5.0
%
mgauss
bits
1.0
degrees
Hz
+10
%
564 counts/gauss
ppm/C
+0.2
8294
gauss
counts
mgauss/C
10000
gauss
gauss
Note: 1: 1.62V is the minimum operation voltage, or VDA / VDD should not be lower than 1.62V.
2: Power consumption is proportional to how many measurements performed per second, for example, at one
measurement per second, the power consumption will be 0.1mA/7=0.014mA.
3: MEMSIC product is with low noise and enables users to utilize heading accuracy to be 0.5 degree typical
and 1.0degree maximum when using MEMSIC‟s proprietary software or algorithm
4. The error can be eliminated by using SET and RESET to determine the true Null Field output for each
measurement.
MEMSIC MMC3316xMT Rev.A
Page 2 of 13
8/10/2012