English
Language : 

GX-5SU Datasheet, PDF (2/16 Pages) List of Unclassifed Manufacturers – Cylindrical Inductive Proximity Sensor Amplifier Built-in
Cylindrical Inductive Proximity Sensor GX-U SERIES GX-FU SERIES GX-N SERIES
796
APPLICATIONS
Detecting traveling aluminum pallets
It can reliably detect even aluminum
pallets because of its long
sensing range.
Controlling depth of drilling
By detecting the dog, the sensor decides
the depth of the
drilled hole.
Positioning object at welding station
(GX-F□U-J only)
It can be safely used even where welding
sparks (spatter) fly around.
ORDER GUIDE
DC 2-wire type
Type Appearance (mm in)
Sensing range (Note)
ø5.4
ø0.213
30
1.181
1.5 mm 0.059 in Maximum operation distance
(0 to 1.2 mm 0 to 0.047 in) Stable sensing range
M8
2 mm 0.079 in
30
1.181
(0 to 1.6 mm 0 to 0.063 in)
3 mm 0.118 in
M12
40.5
1.594
(0 to 2.4 mm 0 to 0.094 in)
7 mm 0.276 in
M18
41.5
1.634
(0 to 5.6 mm 0 to 0.220 in)
M30
44.5
1.752
10 mm 0.394 in
(0 to 8 mm 0 to 0.315 in)
M8
4 mm 0.157 in
30
1.181
(0 to 3.2 mm 0 to 0.126 in)
8 mm 0.315 in
M12
40.5
1.594 (0 to 6.4 mm 0 to 0.252 in)
M18
41.5
1.634
15 mm 0.591 in
(0 to 12 mm 0 to 0.472 in)
Model No.
Output
Output operation
GX-5SU
Normally open
GX-5SUB
Normally closed
GX-8MU
Normally open
GX-8MUB
Normally closed
GX-12MU
Normally open
GX-12MUB
Normally closed
GX-18MU
GX-18MUB
GX-30MU
GX-30MUB
Normally open
Normally closed
Non-contact
DC 2-wire type
Normally open
Normally closed
GX-8MLU
Normally open
GX-8MLUB
Normally closed
GX-12MLU
Normally open
GX-12MLUB
Normally closed
GX-18MLU
Normally open
GX-18MLUB
Normally closed
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
M30
44.5
1.752
22 mm 0.866 in
(0 to 17.6 mm 0 to 0.693 in)
GX-30MLU
GX-30MLUB
Normally open
Normally closed
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.