English
Language : 

GX-5SU Datasheet, PDF (14/16 Pages) List of Unclassifed Manufacturers – Cylindrical Inductive Proximity Sensor Amplifier Built-in
Cylindrical Inductive Proximity Sensor GX-U SERIES GX-FU SERIES GX-N SERIES
808
PRECAUTIONS FOR PROPER USE
All models
Sensing range
• The sensing range is specified for the standard sensing
object. With a non-ferrous metal, the sensing range is
obtained by multiplying with the correction coefficient
specified below. Further, the sensing range also changes
if the sensing object is smaller than the standard sensing
object or if the sensing object is plated.
Correction coefficient
Metal
Iron
Model No.
GX-5SU(B)
1
GX-8MU(B)
1
GX-12MU(B)
GX-F12MU-J
1
GX-18MU(B)
GX-F18MU-J
1
GX-30MU(B)
GX-F30MU-J
1
GX-8MLU(B)
1
GX-12MLU(B)
1
GX-18MLU(B)
1
GX-30MLU(B)
1
GX-N12M(B)
1
GX-N18M(B)
1
GX-N30M(B)
1
GX-N12ML(B)
1
GX-N18ML(B)
1
GX-N30ML(B)
1
Stainless steel
(SUS304)
Brass
Aluminum
0.63 approx. 0.32 approx. 0.30 approx.
0.59 approx. 0.32 approx. 0.29 approx.
0.75 approx. 0.51 approx. 0.49 approx.
0.75 approx. 0.50 approx. 0.48 approx.
0.69 approx. 0.44 approx. 0.42 approx.
0.64 approx. 0.38 approx. 0.38 approx.
0.67 approx. 0.44 approx. 0.43 approx.
0.68 approx. 0.45 approx. 0.43 approx.
0.67 approx. 0.44 approx. 0.43 approx.
0.77 approx. 0.52 approx. 0.51 approx.
0.73 approx. 0.50 approx. 0.48 approx.
0.70 approx. 0.45 approx. 0.44 approx.
0.66 approx. 0.44 approx. 0.43 approx.
0.68 approx. 0.46 approx. 0.44 approx.
0.65 approx. 0.44 approx. 0.43 approx.
Protection cover (Optional)
• It protects the sensing surface from welding sparks
(spatter), etc.
Mounting method
Protection
cover
Sensor
Material: Fluorine resin
Model No.
MS-H12
MS-H18
MS-H30
Applicable model No.
GX-12MU(B)
GX-N12M(B)
GX-18MU(B)
GX-N18M(B)
GX-30MU(B)
GX-N30M(B)
Note: Mount the protection cover so that there is no gap between it and the
sensing surface.
Others
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
Refer to General precautions.
FIBER
SENSORS
DC 2-wire type
Wiring
• The sensor must be connected to a power supply via a load.
If the sensor is connected to a power supply without a load,
the short-circuit protection makes the sensor inoperable.
(The output stays in the OFF state and the indicator does
not light up.) In this case, rectify by connecting the power
supply via a load. Now, the sensor becomes operable.
Further, take care that if the power supply is connected with
reverse polarity without a load, the sensor will get damaged.
Blue lead wire
Brown lead wire
+ DC
– power
supply
+ DC
– power
supply
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Brown lead wire
Blue lead wire
• For series connection (AND circuit) or parallel connection
(OR circuit) of sensors, take care of the following.
Series connection (AND circuit)
When all sensors are in the ON state,
the load voltage VRL is given by:
VRL = VCC – n × 3 (V)
Vcc: s upply voltage
(24 V DC max.)
n: number of sensors
Make sure that the load can
work properly at this voltage.
Note: T he output is generated
normally even if the indicator
does not light up properly.
Brown lead wire
Load
VRL
Blue lead wire +
Brown
– VCC
lead wire
Parallel connection (OR circuit)
When all sensors are in the OFF state,
the load leakage current lcc is given by:
lcc = n × 0.8 (mA) ( n: number of sensors)
Make sure that the load can work properly.
Note: T he load current in the ON state
is given by:
IL =
Vcc – 3V
Load resistance
(mA)
The load current must be
3 mA × n ≤ IL ≤ 70 mA
(n: number of sensors turned ON)
Brown lead wire
Load
Blue
ICC
lead wire
(IL)
Brown
lead wire
+
– VCC
Blue lead wire
Blue lead wire
• The residual voltage of the sensor is 3 V. Before connecting
a relay as the load, take care of its actuation voltage.
(Some 12 V relays may not be usable.)
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
( ) VR Relay actuation
voltage
+
Brown lead wire
–
( ) VS=3 V Residual voltage
when the sensor
is in the ON state
Blue lead wire
Relay actuation
voltage:
VR ≤ 12 – 3 V
≤9V
Power supply
12 V DC
2-color indicator [GX-(F)□U(-J) only]
• When the sensing object is in the stable sensing range,
the LED lights up in green, and when the sensing object
is in the unstable sensing range, the LED lights up in
orange. While the LED lights up in green, the sensing is
performed stably without being affected by temperature
drifts or voltage fluctuations.
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Max.
operation
distance
0
Output operation
Output operation
level
Unstable range
LED lights up
in orange
2-color indicator operation