GMBHR168 Datasheet, PDF (17/70 Pages) List of Unclassifed Manufacturers – Mini BLOCK Housing 16 opto inputs, 8 Relay outputs
ITALIAN TECHNOLOGY
grifo®
ELECTRIC FEATURES
Power supply:
10÷38Vdc ± 5% or 8÷23Vac ± 5% (control logic)
Power required for logic:
5W
Output power supply:
+5 Vdc
Current on +5 Vdc output:
1000 mA - current required - current required by ZC1 hw
Current required by GMB HR168: 542 mA max
32÷150 mA max
(+5 Vdc)
(+V opto)
Relays max current:
5A
(resistive load)
Relays max voltage:
35 Vdc
Power required for optocouplers: 4.4 W
Optocouplers input voltage:
+Vopto = 9÷28 Vdc ± 5% or 9÷23Vac ± 5% (*)
Analog input range:
depends on hardware installed on ZC1
(for grifo® Mini Modules: 0÷2.5 ; 0÷10 V)
Pull-up on I2C BUS dedicated lines: 4.7 kΩ
Termination network RS 422-485: Line termination resistor
Positive pull up resistor
Negative pull down resistor
=120 Ω
=3.3 KΩ
=3.3 KΩ