S-8261ABRMD-G3RT2G Datasheet, PDF (15/33 Pages) List of Unclassifed Manufacturers – BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.5.3_00
BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series
„ Test Circuits
Caution
Unless otherwise specified, the output voltage levels “H” and “L” at CO pin (VCO) and DO pin (VDO) are
judged by the threshold voltage (1.0 V) of the N-channel FET. Judge the CO pin level with respect to
VVM and the DO pin level with respect to VSS.
(1) Test Condition 1, Test Circuit 1
(Overcharge Detection Voltage, Overcharge Hysteresis Voltage)
The overcharge detection voltage (VCU) is defined as the voltage between VDD and VSS at which VCO goes from “H”
to “L” when the voltage V1 is gradually increased from the starting condition of V1 = 3.5 V. The overcharge
hysteresis voltage (VHC) is then defined as the difference between the overcharge detection voltage (VCU) and the
voltage between VDD and VSS at which VCO goes from “L” to “H” when the voltage V1 is gradually decreased.
(2) Test Condition 2, Test Circuit 2
(Overdischarge Detection Voltage, Overdischarge Hysteresis Voltage)
The overdischarge detection voltage (VDL) is defined as the voltage between VDD and VSS at which VDO goes from
“H” to “L” when the voltage V1 is gradually decreased from the starting condition of V1 = 3.5 V and V2 = 0 V. The
overdischarge hysteresis voltage (VHD) is then defined as the difference between the overdischarge detection
voltage (VDL) and the voltage between VDD and VSS at which VDO goes from “L” to “H” when the voltage V1 is
gradually increased.
(3) Test Condition 3, Test Circuit 2
(Overcurrent 1 Detection Voltage, Overcurrent 2 Detection Voltage, Load Short-Circuiting Detection Voltage)
The overcurrent 1 detection voltage (VIOV1) is defined as the voltage between VM and VSS whose delay time for
changing VDO from “H” to “L” lies between the minimum and the maximum value of the overcurrent 1 detection delay
time when the voltage V2 is increased rapidly (within 10 μs) from the starting condition V1 = 3.5 V and V2 = 0 V.
The overcurrent 2 detection voltage (VIOV2) is defined as the voltage between VM and VSS whose delay time for
changing VDO from “H” to “L” lies between the minimum and the maximum value of the overcurrent 2 detection delay
time when the voltage V2 is increased rapidly (within 10 μs) from the starting condition V1 = 3.5 V and V2 = 0 V.
The load short-circuiting detection voltage (VSHORT) is defined as the voltage between VM and VSS whose delay time
for changing VDO from “H” to “L” lies between the minimum and the maximum value of the load short-circuiting
detection delay time when the voltage V2 is increased rapidly (within 10 μs) from the starting condition V1 = 3.5 V
and V2 = 0 V.
(4) Test Condition 4, Test Circuit 2
(Charger Detection Voltage, Abnormal Charge Current Detection Voltage)
The charger detection voltage (VCHA) is defined as the voltage between VM and VSS at which VDO goes from “L” to
“H” when the voltage V2 is gradually decreased from 0 V after the voltage V1 is gradually increased from the starting
condition of V1 = 1.8 V and V2 = 0 V until the voltage V1 becomes V1 = VDL + (VHD / 2).
The charger detection voltage can be measured only in the product whose overdischarge hysteresis VHD ≠ 0.
Set V1 = 3.5 V and V2 = 0 V. Decrease V2 from 0 V gradually. The voltage between VM and VSS when VCO goes
from “H” to “L” is the abnormal charge current detection voltage. The abnormal charge current detection voltage has
the same value as the charger detection voltage (VCHA).
(5) Test Condition 5, Test Circuit 2
(Normal Operation Current Consumption, Power-Down Current Consumption, Overdischarge Current Consumption)
With power-down function
The operating current consumption (IOPE) is the current that flows through the VDD pin (IDD) under the set conditions
of V1 = 3.5 V and V2 = 0 V (Normal status).
The power-down current consumption (IPDN) is the current that flows through the VDD pin (IDD) under the set
conditions of V1 = V2 = 1.5 V (Overdischarge status).
Without power-down function
The operating current consumption (IOPE) is the current that flows through the VDD pin (IDD) under the set conditions
of V1 = 3.5 V and V2 = 0 V (Normal status).
The Overdischarge current consumption (IOPED) is the current that flows through the VDD pin (IDD) under the set
conditions of V1 = V2 = 1.5 V (Overdischarge status).
Seiko Instruments Inc.