English
Language : 

S-8261ABRMD-G3RT2G Datasheet, PDF (12/33 Pages) List of Unclassifed Manufacturers – BATTERY PROTECTION IC FOR 1-CELL PACK
BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series
Rev.5.3_00
(5) S-8261ABI, S-8261ABL, S-8261ABT
Table 12
Test Test
Item
Symbol
Condition
Min. Typ. Max. Unit condition circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time
tCU
⎯
0.96 1.2 1.4 s
9
5
Overdischarge detection delay time
tDL
⎯
29 36
43 ms
9
5
Overcurrent 1 detection delay time
tlOV1
⎯
7.2
9
11 ms 10
5
Overcurrent 2 detection delay time
tlOV2
⎯
1.8 2.24 2.7 ms 10
5
Load short-circuiting detection delay time tSHORT
⎯
DELAY TIME (Ta = −40°C to +85°C) *1
220 320 380 μs 10
5
Overcharge detection delay time
tCU
⎯
Overdischarge detection delay time
tDL
⎯
Overcurrent 1 detection delay time
tlOV1
⎯
Overcurrent 2 detection delay time
tlOV2
⎯
Load short-circuiting detection delay time tSHORT
⎯
0.7 1.2 2.0 s
9
5
20 36
61 ms
9
5
5
9
15 ms 10
5
1.2 2.24 3.8 ms 10
5
150 320 540 μs 10
5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design,
not tested in production.
(6) S-8261ABY, S-8261ABZ, S-8261ACA, S-8261ACS
Table 13
Item
Symbol
Condition
Min. Typ. Max. Unit Test Test
Condition Circuit
DELAY TIME (Ta = 25°C)
Overcharge detection delay time
tCU
⎯
0.96 1.2 1.4 s
9
5
Overdischarge detection delay time
tDL
⎯
115 144 173 ms
9
5
Overcurrent 1 detection delay time
tlOV1
⎯
7.2
9
11 ms 10
5
Overcurrent 2 detection delay time
tlOV2
⎯
0.89 1.12 1.35 ms 10
5
Load short-circuiting detection delay time tSHORT
⎯
DELAY TIME (Ta = −40°C to +85°C) *1
220 320 380 μs 10
5
Overcharge detection delay time
tCU
⎯
0.7 1.2 2.0 s
9
5
Overdischarge detection delay time
tDL
⎯
80 144 245 ms
9
5
Overcurrent 1 detection delay time
tlOV1
⎯
5
9
15 ms 10
5
Overcurrent 2 detection delay time
tlOV2
⎯
0.61 1.12 1.91 ms 10
5
Load short-circuiting detection delay time tSHORT
⎯
150 320 540 μs 10
5
*1. Since products are not screened at high and low temperatures, the specification for this temperature range is guaranteed by design,
not tested in production.
12
Seiko Instruments Inc.