4.3 Electronic Static Discharge maximum rating
ESD test method : IEC1000-4-2
Item
Testing environment
Testing equipment
Testing condition
Direct discharge
Indirect discharge
Pass condition
Fail condition
Description
Ambient temperature :15°C to 35 °C
Humidity: 30% to 60 %
LCM ( E.U.T ) : Power up
Manufacture: NoiseKen, Model No. ESD-100L
See drawing 1
0 to ± 6 KV Discharge point, see drawing 2
0 to ± 12KV Discharge point, see drawing 1
No malfunction of unit. Temporary malfunction of unit which
can be recovered by system reset
Non. Recoverable malfunction of LCM or system
FIG 1 ESD TESTING EQUIPM ENT
HCP INDIRECT DISCHARGE
DIRECT DISCHARGE
VCP INDIRECT DISCHARGE
GROUND LEVEL
470k
IS O L A T O R
ESD POWER SUPPLY
HCP
W OODEN TABLE(TALL 0.8m )
(1)