English
Language : 

SD1010A Datasheet, PDF (32/45 Pages) List of Unclassifed Manufacturers – Analog-Interface XGA TFT LCD Display Controller
SmartASIC, Inc.
SD1010A
Clock Phase Source 10
VPW standalone 11
VTOTAL standalone 11
HPW standalone 11
HTOTAL standalone 11
Disable auto
1
calibration for mode
640x350
Delay auto
15
calibration for mode
640x350
Disable auto
1
calibration for mode
640x400
Delay auto
15
calibration for mode
640x400
Disable auto
1
calibration for mode
720x400
Delay auto
15
calibration for mode
720x400
Disable auto
1
calibration for mode
640x480
Delay auto
15
calibration for mode
640x480
Disable auto
1
calibration for mode
800x600
Delay auto
15
calibration for mode
800x600
Disable auto
1
calibration for mode
832x624
Delay auto
15
calibration for mode
832x624
Disable auto
1
calibration for mode
1024x768
Delay auto
15
calibration for mode
1024x768
Disable auto
1
calibration for mode
INVALID
November, 1999
Revision B
11: user defined mode 5
12: user defined mode 6
13: user defined mode 7
14-15: error
RW DH-EH Input sampling clock phase
RW FH-10H For standalone mode, the pulse width of VSYNC
RW 11H-12H For standalone mode, total number of line per frame
RW 13H-14H For standalone mode, HSYNC active time in µs
RW 15H-16H For standalone mode, HSYNC cycle time in µs
RW 17H[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 17H[6:0]- The number of frames need to be skipped before
18H starting auto calibration for this mode
RW 19H[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 19H[6:0]- The number of frames need to be skipped before
1AH starting auto calibration for this mode
RW 1BH[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 1BH[6:0]- The number of frames need to be skipped before
1CH starting auto calibration for this mode
RW 1DH[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 1DH[6:0]- The number of frames need to be skipped before
1EH starting auto calibration for this mode
RW 1FH[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 1FH[6:0]- The number of frames need to be skipped before
20H starting auto calibration for this mode
RW 21H[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 21H[6:0]- The number of frames need to be skipped before
22H starting auto calibration for this mode
RW 23H[7] Disable auto calibration for this mode:
1: disable
0: enable
RW 23H[6:0]- The number of frames need to be skipped before
24H starting auto calibration for this mode
RW 25H[7] Disable auto calibration for this mode:
1: disable
0: enable
SmartASIC Confidential
32