English
Language : 

Q2406 Datasheet, PDF (44/81 Pages) List of Unclassifed Manufacturers – SELF CONTAINED E GSM/GPRS 900/1800 OR 850/1900 BI BAND MODULE
WM_PRJ_Q2400_PTS_002 - 002
24th January 2003
2.16.1 Reset sequence
To activate the « emergency » reset sequence, the ~RST signal has to be set to
low for 500µs minimum. As soon as the reset is complete, the AT interface
answers « OK » to the application4.
EXTERNAL RST
Min:500µs
Typ:2ms
AT answers “OK”
Module READY
STATE OF THE MODULE
Module ON Module READY
RESET mode IBB+RF<120mA
IBB+RF=20 to without loc update
40mA
SIM and network dependent
Figure 14 : Reset sequence
2.17 External Interrupt (~INTR)
The WISMO Quik Q24x6 Series provides an external interrupt input (not
managed in the standard AT commands firmware). This input is very sensitive
and an interrupt is activated on high to low edge. If this signal is not used it
can be left open. If used this input has to be driven by an open collector or an
open drain.
This input is used for instance to power OFF automatically the module.
Pin description
Signal
~INTR
Pin number I/O
16
I
I/O type
CMOS
Description
External Interrupt
Electrical characteristics
Parameter
VIL
VIH
Min
-0.5V
2.2V
Max
0.7V
3.0V
Unit
Volt
Volt
4 For this, the application has to send AT↵. If the application manages hardware flow control, the
AT command can be sent during the initialisation phase. Another solution is to use the +WIND
command to get an unsollicited status from the module.
confidential ©
Page : 44 / 81
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à
des tiers sans son autorisation préalable.