English
Language : 

Q2406 Datasheet, PDF (32/81 Pages) List of Unclassifed Manufacturers – SELF CONTAINED E GSM/GPRS 900/1800 OR 850/1900 BI BAND MODULE
WM_PRJ_Q2400_PTS_002 - 002
24th January 2003
L1, L2, C3 and C4 has to be put near the WISMO Quik Q24x6 Series connector
and can be removed according to their environment (ground plane, shielding
...etc). The best way is to plan all the components and to remove those which
are not necessary to filter out the TDMA noise on the audio path.
2.12.1.3.2
Single-ended connection
Typical implementation:
VAUDIO
R1
L2
C4
R2
L1
C5
C3
MIC1P
C1
MIC1N
C2
Figure 5 : MIC1 inputs (single-ended connection)
Note : VAUDIO must be very “clean” in single-ended connection (for example,
VCC plus filter cell like RC or LC).
R1 = from 100 to 330Ω
R2 = usually between 1KΩ and 3.3KΩ as per the VAUDIO voltage level and the
microphone characteristics
C1 = 10pF to 33pF
C2 = C3 = C5 = 47pF to 100pF
C4 = 47µF
L1 = L2 = 100nH
R1 is used as a voltage supply filter with C4.
C5 has to be the nearest possible to the microphone. Microphone
manufacturers provide this capacitor directly soldered on the microphone.
C1, C2, C3 have to be very close to the WISMO Quik Q24x6 Series connector.
L1, and L2 has to be put near the WISMO Quik Q24x6 Series connector and
can be removed according to their environment (ground plane, shielding ...etc).
The best way is to plan all the components and to remove those which are not
necessary to filter out the TDMA noise on the audio path.
confidential ©
Page : 32 / 81
This document is the sole and exclusive property of WAVECOM. Not to be distributed or divulged
without prior written agreement.
Ce document est la propriété exclusive de WAVECOM. Il ne peut être communiqué ou divulgué à