6.6.1 Port Options Register
Bit:
7
6
5
4
-
-
-
-
Mnemonic: POR
3
2
-
-
Address: 86H
1
0
-
P0UP
P0UP: Enable Port 0 weak up. The pins of Port 0 can be configured with either the open drain or
standard port with internal pull-up. By the default, Port 0 is an open drain bi-directional I/O port. When
the P0UP bit in the POR register is set, the pins of port 0 will perform a bi-directional I/O port with
internal pull-up that is structurally the same Port2.
6.6.2 INT2 / INT3
Two additional external interrupts, INT2 and INT3 , whose functions are similar to those of external
interrupt 0 and 1 in the standard 80C52. The functions/status of these interrupts are
determined/shown by the bits in the XICON (External Interrupt Control) register. The XICON register is
bit-addressable but is not a standard register in the standard 80C52. Its address is at 0C0H. To
set/clear bits in the XICON register, one can use the "SETB ( CLR ) bit" instruction. For example,
"SETB 0C2H" sets the EX2 bit of XICON.
XICON - external interrupt control (C0H)
PX3
EX3
IE3
IT3
PX2
EX2
IE2
IT2
PX3: External interrupt 3 priority high if set
EX3: External interrupt 3 enable if set
IE3: If IT3 = 1, IE3 is set/cleared automatically by hardware when interrupt is detected/serviced
IT3: External interrupt 3 is falling-edge/low-level triggered when this bit is set/cleared by software
PX2: External interrupt 2 priority high if set
EX2: External interrupt 2 enable if set
IE2: If IT2 = 1, IE2 is set/cleared automatically by hardware when interrupt is detected/serviced
IT2: External interrupt 2 is falling-edge/low-level triggered when this bit is set/cleared by software
- 10 -