English
Language : 

EN29GL064 Datasheet, PDF (26/66 Pages) Eon Silicon Solution Inc. – 64 Megabit (8192K x 8-bit / 4096K x 16-bit) Flash Memory
Preliminary EN29GL064
Polling on DQ7 is active for approximately 100 µs, then the device returns to the read mode. If not all
selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and
ignores the selected sectors that are protected. However, if the system reads DQ7 at an address within
a protected sector, the status may not be valid.
Just prior to the completion of an Embedded Program or Erase operation, DQ7 may change
asynchronously with DQ6-DQ0 while Output Enable (OE#) is asserted low. That is, the device may
change from providing status information to valid data on DQ7. Depending on when the system samples
the DQ7 output, it may read the status or valid data. Even if the device has completed the program or
erase operation and DQ7 has valid data, the data outputs on DQ6-DQ0 may be still invalid. Valid data
on DQ7-D00 appears on successive read cycles.
This Data Sheet may be revised by subsequent versions
26
or modifications due to changes in technical specifications.
©2004 Eon Silicon Solution, Inc.,
Rev. A, Issue Date: 2009/3/20
www.eonssi.com