English
Language : 

EN29LV160A Datasheet, PDF (24/43 Pages) Eon Silicon Solution Inc. – 16 MEGABIT (2048K X 8- BIT / 1024 K X 16-BIT) FLASH MEMORY
Flowchart 7b. In-System Sector Unprotect Flowchart
START
EN29LV160A
Protect all sectors:
The indicated portion
of the sector protect
algorithm must be
performed for all
unprotected sectors
prior to issuing the
first sector unprotect
address (see
Diagram 7a.)
PLSCNT = 1
RESET# = VID
Wait 1 µS
No
First Write
Cycle = 60h?
Yes
No
All sectors
protected?
Yes
Set up first sector
address
Sector Unprotect: Write 60H to
sector address with A6 = 1,
A1 = 1, A0 = 0
Temporary Sector
Unprotect Mode
Increment
PLSCNT
Wait 15 ms
Verify Sector Unprotect:
Write 40h to sector address
with A6 = 1, A1 = 1, A0 =0
Wait 0.4 µS
Read from sector address with
A6 = 1, A1 = 1, A0 = 0
No
Sector
Unprotect
Algorithm
PLSCCNT =
1000?
Yes
Device failed
No
Data = 00h?
Set up next sector
address
Yes
Last sector
No
verified?
Yes
Remove VID from
RESET#
Write reset
command
Sector Unprotect
complete
This Data Sheet may be revised by subsequent versions 24 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw
or modifications due to changes in technical specifications.
Rev. C, Issue Date: 2005/01/07