MA28155 Datasheet, PDF (16/20 Pages) Dynex Semiconductor – Radiation Hard Programmable Peripheral Interface | |||
|
◁ |
MA28155
AC ELECTRICAL CHARACTERISTICS
Parameter
Min. Max. Units
Parameter
Min. Max Units
18 DSN â to lBF â
-
65 ns
19 Peripheral Data set up to STBN â 0
ns
1 DSN width
65 -
ns 20 Peripheral Data hold after STBN â 100
ns
2 Peripheral Data set up to DSN 0 -
ns 21 DSN â to INTR â (note 4)
-
DS+ ns
100
3 Peripheral Data hold after DSN 10 -
ns 22 Output valid from DSN â
-
100 ns
4 CSN, A1, A0 setup to DSN â
0-
ns 23 DSN â to OBFN â
-
105 ns
5 CSN, A1, A0 hold after DSN â 0
-
ns 24 ACKN â to OBFN â
-
50 ns
6 Data valid from DSN â
-
60 ns 25 ACKN pulse width
100 -
ns
7 Data float from DSN â (note 5) 10 100 ns 26 ACKN â INTR â
-
80 ns
8 Data set up to DSN â
20 -
ns 27 DSN â to OBFN â
-
105 ns
9 Data hold after DSN â
30 -
ns 28 STBN pulse width
100 -
ns
10 CSN, A1, A0 setup to DSN â
0
-
ns 29 STBN â to IBF â
-
65 ns
11 CSN, A1, A0 hold after DSN â 20 -
ns 30 Peripheral Data set up to STBN â 0
-
ns
12 Output valid from DSN â
-
100 ns 31 Perlpheral Data hold after STBN â 100 -
ns
14 STBN pulse width
100 -
ns 32 Output valid from ACKN â
-
45 ns
15 STBN â to IBF â
-
65 ns 33 Output float from ACKN â (Note 5) 10 100 ns
16 STBN â to INTR â
-
65 ns 34 ACKN â to OBFN â
-
50 ns
17 DSN â, to INTR â
-
65 ns 35 DSN â to IBF â
-
65 ns
Mil-Std-883, method 5005, subgroup 9, 10, 11.
1. VDD = 5V±10% and CCL = 50pF, over full operating temperature range.
2. Input Pulse VSS to 3.0 Volts.
3. Times Measurement Reference Level 1.5 Volts.
4. DSN = Data Strobe Pulse Width.
5. Measured by a 1.0 Volt change in output voltage. Outputs tied to VSS via 680â¦.
Table 6: AC Electrical Characteristics
16/20
|
▷ |