English
Language : 

MB3773 Datasheet, PDF (22/31 Pages) Fujitsu Component Limited. – Power Supply Monitor with Watch-Dog Timer
MB3773
VCC(  5
CT
EXAMPLE 9: Reducing Reset Hold Time
VCC (  5 V)
MB3773
1
8
2
7
3
6
4
5
Logic circuit
RESET
RESET
CK
CT
GND
MB3773
1
8
2
7
3
6
4
5
Logic circuit
RESET
RESET
CK
GND
(a) TPR reduction method
(b) Standard usage
Notes :
• RESET is the only output that can be used.
• Standard TPR, TWD and TWR value can be found using the following formulas.
Formulas:TPR (ms) =: 100 × CT (μF)
TWD (ms) =: 100 × CT (μF)
TWR (ms) =: 16 × CT (μF)
• The above formulas become standard values in determining TPR, TWD and TWR.
Reset hold time is compared below between the reduction circuit and the standard circuit.
CT  0.1 μF
TPR =:
TWD =:
TWR =:
TPR reduction circuit
10 ms
10 ms
1.6 ms
Standard circuit
100 ms
10 ms
2.0 ms
Document Number: 002-08513 Rev. *A
Page 22 of 31