English
Language : 

CPC7581_1 Datasheet, PDF (9/17 Pages) Clare, Inc. – Line Card Access Switch
CPC7581
1.8 Protection Circuitry Electrical Specifications
Parameter
Conditions
Symbol Minimum Typical Maximum
Unit
Parameters Related to the Diodes in the Diode Bridge
Voltage drop at
continuous current (50/
60 Hz)
Apply ± dc current limit of break
switches
Forward
Voltage
-
2.1
3
V
Voltage drop at surge Apply ± dynamic current limit of break
current
switches
Forward
Voltage
-
5
-
Parameters Related to the Protection SCR
Surge current
-
-
-
-
*
A
Trigger current
Hold current
T=+25°C
T=+85°C
T=+25°C
T=+85°C
60
(CPC7581xA)
70
(CPC7581xC)
ITRIG
35
-
(CPC7581xA)
40
(CPC7581xC)
-
mA
110
(CPC7581xA)
135
IHOLD
(CPC7581xC)
60
70
(CPC7581xA) (CPC7581xA)
110
115
(CPC7581xC) (CPC7581xC)
Gate trigger voltage IGATE = ITRIGGER**
VTBAT or
VRBAT
VBAT -4
-
VBAT -2
V
Reverse leakage current VBAT = -48 V
IVBAT
-
-
1.0
μA
On-state voltage
0.5 A, t = 0.5 μs
2.0 A, t = 0.5 μs
VTBAT or
-
-3
-
V
VRBAT-
-
-5
-
V
*Passes GR1089 and ITU-T K.20 with appropriate secondary protection in place.
**VBAT must be capable of sourcing ITRIGGER for the internal SCR to activate.
1.9 Truth Table
State
INRINGING
Latch
TSD
Break
Switches
Ringing Switches
Talk
0
Ringing
1
On
Off
0
Z1
Off
On
Latched
X
1
Unchanged
All-Off
X
X
0
Off
Off
1 Z = High Impedance. Because TSD has an internal pull up at this pin, it should be controlled with an open-collector or open-drain type device.
R05
www.clare.com
9