English
Language : 

CPC7581_1 Datasheet, PDF (7/17 Pages) Clare, Inc. – Line Card Access Switch
1.6.3 Ringing Switch, SW4
Parameter
Conditions
Symbol Minimum
Off-state leakage current
+25° C
VSW (differential) = -255 V to +210 V
VSW (differential) = +255 V to -210 V
+85° C
VSW (differential) = -270 V to +210 V
VSW (differential) = +270 V to -210 V
ISW
-40° C
VSW (differential) = -245 V to +210 V
VSW (differential) = +245 V to -210 V
On Voltage
ISW (on) = ± 1 mA
-
Ringing generator
current to ground during VDD = 5 V, INRINGING = 0
ringing
-
IRINGING
On steady-state current* Inputs set for ringing mode
ISW
Surge current*
Ringing switches on, all other switches
off, apply ±1 kV at 10x1000 μs pulse,
-
with appropriate protection in place.
Release current
-
RON
ISW (on) = ±70 mA, ±80 mA
Logic input to switch output isolation
IRINGING
RON
+25° C
VSW (RRINGING, RLINE) = ±320 V, logic
inputs = gnd
+85° C
VSW (RRINGING, RLINE) = ±330 V, logic
inputs = gnd
ISW
-
-40° C
VSW (RRINGING, RLINE) = ±310 V, logic
inputs = gnd
dv/dt sensitivity
-
-
*Secondary protection and ringing source current limiting must prevent exceeding this parameter.
Typical
0.05
0.1
0.05
1.5
0.1
-
-
300
10
0.1
0.3
0.1
200
CPC7581
Maximum
Unit
1
μA
3
V
0.25
mA
150
mA
2
A
-
μA
15
Ω
1
μA
-
V/μs
R05
www.clare.com
7