2. CHARACTERISTICS AND SPECIFICATIONS
CS4362A
RECOMMENDED OPERATING CONDITIONS
(GND = 0 V; all voltages with respect to ground.)
Parameters
Symbol Min Typ Max Units
DC Power Supply
Analog Power VA
4.75
5.0
5.25
V
Digital Internal Power VD
2.37
2.5
2.63
V
Serial Data Port Interface Power VLS
1.71
5.0
5.25
V
Control Port Interface Power VLC
1.71
5.0
5.25
V
Ambient Operating Temperature (power applied)
Commercial Grade (-CQZ)
TA
-40
-
+85
°C
Automotive Grade (-DQZ)
-40
-
+105
°C
ABSOLUTE MAXIMUM RATINGS
(GND = 0 V; all voltages with respect to ground.)
Parameters
Symbol
Min
Max
Units
DC Power Supply
Analog Power
VA
-0.3
Digital Internal Power
VD
-0.3
Serial Data Port Interface Power VLS
-0.3
Control Port Interface Power VLC
-0.3
6.0
V
3.2
V
6.0
V
6.0
V
Input Current
Any Pin Except Supplies
Iin
-
±10
mA
Digital Input Voltage
Serial Data Port Interface VIND-S
-0.3
VLS+ 0.4
V
Control Port Interface VIND-C
-0.3
VLC+ 0.4
V
Ambient Operating Temperature (power applied)
Top
-55
125
°C
Storage Temperature
Tstg
-65
150
°C
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.
8