1) Cable Connection and Disconnection
Do not connect and disconnect the LVDS cable, when the power is supplied to the system.
2) GND Connection
Connect each GND of the PCB which THC63LVD1022 and LVDS-Tx on it. It is better for EMI reduction
to place GND cable as close to LVDS cable as possible.
3) Multi Drop Connection
Multi drop connection is not recommended.
LVDS-Tx
TCLK+
TCLK-
THC63LVD1022
THC63LVD1022
Figure 12. Multi Drop Connection
4) Asynchronous use
Asynchronous using such as following system is not recommended.
Figure 13. Asynchronous Use