English
Language : 

CS4365 Datasheet, PDF (6/51 Pages) Cirrus Logic – 114 dB, 192 kHz 6-Channel D/A Converter
1. PIN DESCRIPTION
48 47 46 45 44 43 42 41 40 39 38 37
DSDA2
DSDB1
DSDA1
VD
GND
MCLK
LRCK
SDIN1
SCLK
M4(TST)
SDIN2
M3(TST)
1
36
2
35
3
34
4
33
5
32
6
CS4365
31
7
30
8
29
9
28
10
27
11
26
12
25
13 14 15 16 17 18 19 20 21 22 23 24
AOUTA2-
AOUTA2+
AOUTB2+
AOUTB2-
VA
GND
AOUTA3-
AOUTA3+
AOUTB3+
AOUTB3-
MUTEC2
MUTEC3
CS4365
Pin Name
VD
GND
MCLK
LRCK
SDIN1
SDIN2
SDIN3
SCLK
TST
RST
VA
VLS
VLC
6
#
Pin Description
4 Digital Power (Input) - Positive power supply for the digital section. Refer to the Rec-
ommended Operating Conditions for appropriate voltages.
5 Ground (Input) - Ground reference. Should be connected to analog ground.
31
6 Master Clock (Input) - Clock source for the delta-sigma modulator and digital filters.
Table 5 illustrates several standard audio sample rates and the required master clock
frequencies.
7 Left Right Clock (Input) - Determines which channel, Left or Right, is currently active
on the serial audio data line. The frequency of the left/right clock must be at the audio
sample rate, Fs.
8 Serial Data Input (Input) - Input for two’s complement serial audio data.
11
13
9 Serial Clock (Input) - Serial clocks for the serial audio interface.
14 Test - These pins need to be tied to analog ground.
44
45
19 Reset (Input) - The device enters a low power mode and all internal registers are
reset to their default settings when low.
32 Analog Power (Input) - Positive power supply for the analog section. Refer to the
Recommended Operating Conditions for appropriate voltages.
43 Serial Audio Interface Power (Input) - Determines the required signal level for the
serial audio interface. Refer to the Recommended Operating Conditions for appropri-
ate voltages.
18 Control Port Power (Input) - Determines the required signal level for the control port
and hardware mode configuration pins. Refer to the Recommended Operating Condi-
tions for appropriate voltages.
DS670PP1