PISCES II DC/DC CONVERTERS
48V Input – 1.2VDC – 60A Output
POWER PRODUCTS
G2PW1V260
Isolation Specifications
Parameter
Isolation Test Voltage, Input/Output (Basic)
Isolation Test Voltage, Input/Case
Isolation Test Voltage, Output Case
Isolation Resistance
Min
Typical
Max
2250
2000
500
10
Units
VDC
VDC
VDC
MΩ
Features
Parameter
Over Temperature Protection, Thermal Sensor, Latching2
Switching Frequency, Fixed
2. PCB less than 130˚ C.
Min
Typical
Max
110
250
Units
˚C
kHz
General Specifications
Operating Temperature
Storge Temperature
Relative Humidity
Vibration
Material Flammability
Weight
MTBF Telcordia (Bellcore)
-40˚ C to + 100˚ C
-55˚ C + 125˚ C
10% to 95% RH, Non-condensing
2 to 9 Hz, 3mm disp., 9 to 200 Hz, 1g
UL V-0
35 grams
1.6 million hours
Approvals and Standards
UL and c-UL Recognized Component, TUV**,
UL60950, CSA 22.2 No. 950, IEC/EN 60950
EMC Characteristics:
Designed to meet emission and immunity
requirements per EN55022, CISPR 22,
Class B, and CISPR 24.
** An external fuse shall be used to comply with
the requirements.