English
Language : 

SLIN-06E2A_10 Datasheet, PDF (20/25 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.59 Vdc - 5.5 Vdc /6 A Outputs
December 3, 2010
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Thermal Considerations (continued)
The thermal reference points, Tref used in the specifications are also shown in below. For reliable operation the
temperatures at these points should not exceed 120oC. The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Preferred airflow direction and location of hot-spot of the module (Tref).
Example Application Circuit
Requirements:
Vin:
12V
Vout:
1.8V
Iout:
4.5A max., worst case load transient is from 3A to 4.5A
ΔVout:
1.5% of Vout (27mV) for worst case load transient
Vin, ripple
1.5% of Vin (50mV, p-p)
Vin+
VIN
VOUT
SENSE
+
CI2
MODULE
CI1
Q3 ON/OFF
TRIM
GND
Vout+
RTUNE
CTUNE
CO1
RTrim
CI1
CI2
CO1
CTune
RTune
RTrim
22μF/16V ceramic capacitor (e.g. Murata GRM32ER61C226KE20)
47μF/16V bulk electrolytic
5 x 47μF/6.3V ceramic capacitor (e.g. Murata GRM31CR60J476ME19)
12nF ceramic capacitor (can be 1206, 0805 or 0603 size)
120 ohms SMT resistor (can be 1206, 0805 or 0603 size)
4.87kΩ SMT resistor (can be 1206, 0805 or 0603 size, recommended tolerance of 0.1%)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com