English
Language : 

SLIN-06E2A_10 Datasheet, PDF (19/25 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.59 Vdc - 5.5 Vdc /6 A Outputs
December 3, 2010
Tunable LoopTM (Continued)
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Table 2.General recommended values of RTUNE and CTUNE for Vin=12V and various external ceramic capacitor
combinations.
Co
RTUNE
CTUNE
1x47μF
270
2200pF
2x47μF
220
4700pF
4x47μF
150
8200pF
6x47μF
75
12nF
10x47μF
75
18nF
Table 3.Recommended values of RTUNE and CTUNE to obtain transient deviation of ≤2% of Vout for a 3A step load
with Vin=12V.
Vo
Co
RTUNE
CTUNE
ΔV
5V
2x47μF
220
3900pF
87mV
3.3V
3x47μF
180
6800pF
57mV
2.5V
4x47μF
150
10nF
43mV
1.8V
6x47μF
120
12nF
32mV
1.2V
2x47μF+330μF
Polymer
100
15nF
23mV
0.6V
3 x330μF
Polymer
100
120nF
12mV
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel.
Wind Tunnel
25.4_
(1.0)
PWBs
Power Module
76.2_
(3.0)
x
12.7_
(0.50)
Air
flow
Probe Location
for measuring
airflow and
ambient
temperature
Thermal Test Setup
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
19