English
Language : 

SLIN-06E2A_10 Datasheet, PDF (11/25 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.59 Vdc - 5.5 Vdc /6 A Outputs
December 3, 2010
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Test Configurations
Input Reflected Ripple Current Test Setup.
TO OSCILLOSCOPE
CURRENT PROBE
LTEST
1μH
VIN(+)
CS 1000μF
Electrolytic
E.S.R.<0.1Ω
@ 20°C 100kHz
CIN
2x100μF
Tantalum
COM
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 1μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Output Ripple and Noise Test Setup
COPPER STRIP
Vo+
0.1u F
10uF
RES IS TI VE
LOAD
COM
SCOPE USING
BNC SOCKET
GROUND PLANE
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
r es is ta nc e.
Output Voltage and Efficiency Test Setup
Rdistribution Rcontact
VIN(+)
VO
Rcontact Rdistribution
VIN
VO
RLOAD
Rdistribution Rcontact
COM COM
Rcontact Rdistribution
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Efficiency η =
VO. IO
VIN. IIN
x 100 %
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
11