HCPL-7800-500E Datasheet, PDF (6/18 Pages) AVAGO TECHNOLOGIES LIMITED – 15 kV/μs Common-Mode Rejection at VCM = 1000 V
Insulation and Safety Related Specifications
Parameter
Symbol
Minimum External Air Gap
(Clearance)
L(101)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
L(102)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
Value
7.4
8.0
0.5
>175
III a
Unit
mm
mm
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group
(DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Supply Voltage
Steady-State Input Voltage
2 Second Transient Input Voltage
Output Voltage
Solder Reflow Temperature Profile
Symbol
Min.
Max.
Unit
Note
TS
-55
TA
- 40
VDD1, VDD2
0
VIN+, VIN-
-2.0
-6.0
125
°C
100
5.5
V
VDD1 +0.5
VOUT
-0.5
VDD2 +0.5
See Maximum Solder Reflow Thermal Profile Section
Recommended Operating Conditions
Parameter
Symbol
Min.
Max.
Unit
Note
Ambient Operating Temperature
TA
-40
85
°C
Supply Voltage
VDD1, VDD2
4.5
5.5
V
Input Voltage (accurate and linear)
VIN+, VIN-
-200
200
mV
1
Input Voltage (functional)
VIN+, VIN-
-2
2
V