CODEA_KEY2
Access: Read/Write
Address: 0xC4
Reset Value: 0x00
Type: OTP
Bit
7
6
5
4
3
2
1
0
Field
SC_A7
SC_A6
SC_A5
SC_A4
SC_A3
SC_A2
SC_A1
SC_A0
Data Type: 8-Bit number
USAGE: This register is used together with CODEA_KEY1 register to form CodeA for KM1 output. Any keyboard key scan
codes listed in Keyboard Scan Code Specification Windows Platform Design Notes can be used but only limited
to one scan code.
CodeA = CODEA_KEY1 + CODEA_KEY2
For 3D flip application, CodeA = Alt + Tab
CODEA_KEY1 = 0x40 (R-Alt = 1) or 0x04 (L-Alt = 1)
CODEA_KEY2 = 0x2B (Tab key)
CODEB_KEY2
Access: Read/Write
Address: 0xC5
Reset Value: 0x00
Type: OTP
Bit
7
6
5
4
3
2
1
0
Field
SC_A7
SC_A6
SC_A5
SC_A4
SC_A3
SC_A2
SC_A1
SC_A0
Data Type: 8-Bit number
USAGE: This register is used together with CODEA_KEY1 register to form CodeA for KM2 output. Any keyboard key scan
codes listed in Keyboard Scan Code Specification Windows Platform Design Notes can be used but only limited
to one scan code.
CodeB = CODEB_KEY1 + CODEB_KEY2
For Windows Security Logon/Logout application, CodeB = Alt + Ctrl + Del
CODEB_KEY1 = 0x05 (L-Alt = 1, L-Ctrl = 1)
CODEB_KEY2 = 0x4C (Del key)
LONGPRESS
Access: Read/Write
Address: 0xC6
Reset Value: 0x10
Type: OTP
Bit
7
6
5
4
3
2
1
0
Field
L_Press7
L_Press6
L_Press5
L_Press4
L_Press3
L_Press2
L_Press1
L_Press0
Data Type: 8-Bit number
USAGE: This register is used to set the button press duration for OTF_L. The press duration is range from 16ms to 4s. Each
bit step change is 16ms.