English
Language : 

HCPL-M454 Datasheet, PDF (4/12 Pages) Agilent(Hewlett-Packard) – Ultra High CMR, Small Outline, 5 Lead, High Speed Optocoupler
Recommended Pb-Free IR Profile
tp
Tp
260 +0/-5 °C
TL 217 °C
RAMP-UP
3 °C/SEC. MAX.
Tsmax 150 - 200 °C
Tsmin
ts
PREHEAT
tL
60 to 180 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
20-40 SEC.
RAMP-DOWN
6 °C/SEC. MAX.
60 to 150 SEC.
25
t 25 °C to PEAK
TIME
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
Tsmax = 200 °C, Tsmin = 150 °C
Note: Non-halide flux should be used.
Schematic
ICC 6
VCC
Land Pattern Recommendation
4.4
(0.17)
+ IF
ANODE
1
VF
–
CATHODE
3
SHIELD
IO 5
VO
4
GND
2.5
(0.10)
1.3
(0.05)
2.0
(0.080)
8.27
(0.325)
DIMENSION IN MILLIMETERS (INCHES)
0.64
(0.025)
HCPL-M454 Schematic
Insulation Related Specifications
Parameter
Symbol Value Units
Minimum External Air Gap
L(IO1)
≥5
mm
(Clearance)
Minimum External Tracking Path
L(IO2)
≥5
mm
(Creepage)
Minimum Internal Plastic Gap
0.08
mm
(Clearance)
Tracking Resistance
CTI
175
V
Isolation Group (per DIN VDE 0109)
IIIa
Conditions
Measured from input terminals
to output terminals
Measured from input terminals
to output terminals
Through insulation distance
conductor to conductor
DIN IEC 112/VDE 0303 Part 1
Material Group DIN VDE 0109