Absolute Maximum Ratings
(No Derating Required up to 85°C)
Storage Temperature..............................................................................-55°C to +125°C
Operating Temperature......................................................................... -55°C to +100°C
Average Input Current - IF ..................................................................................25 mA[1]
Peak Input Current - IF .........................................................................................50 mA[2]
(50% duty cycle, 1 ms pulse width)
Peak Transient Input Current - IF .............................................................................1.0 A
(≤1 µs pulse width, 300 pps)
Reverse Input Voltage - VR (Pin 3-1).............................................................................5 V
Input Power Dissipation......................................................................................45 mW[3]
Average Output Current - IO (Pin 5)........................................................................ 8 mA
Peak Output Current..................................................................................................16 mA
Output Voltage - VO (Pin 5-4)......................................................................-0.5 V to 20 V
Supply Voltage - VCC (Pin 6-4).....................................................................-0.5 V to 30 V
Output Power Dissipation............................................................................... 100 mW[4]
Infrared and Vapor Phase Reflow Temperature........................................ see below
Solder Reflow Thermal Profile
300
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC. PEAK
TEMP.
245°C
200
160°C
150°C
140°C
100
2.5°C ± 0.5°C/SEC.
3°C + 1°C/–0.5°C
PREHEATING TIME
150°C, 90 + 30 SEC.
30
SEC.
30
SEC.
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
SOLDERING
TIME
200°C
50 SEC.
ROOM
TEMPERATURE
00
TIGHT
TYPICAL
LOOSE
50
100
150
200
250
TIME (SECONDS)
Note: Non-halide flux should be used.