English
Language : 

TCS3400 Datasheet, PDF (5/35 Pages) ams AG – Single Device Integrated Optical Solution
TCS3400 − Electrical Characteristics
Electrical Characteristics
Figure 6:
Recommended Operating Conditions
All limits are guaranteed. The parameters with min and max
values are guaranteed with production tests or SQC (Statistical
Quality Control) methods.
Symbol
VDD
TA
Parameter
Supply voltage
Operating free-air temperature (1)
Min
Typ
Max Units
2.7
3
3.6
V
-40
70
°C
Note(s):
1. While the device is operational across the temperature range, functionality will vary with temperature. Specifications are stated at
25°C unless otherwise noted.
Figure 7:
Operating Characteristics, VDD=3V, TA=25ºC (unless otherwise noted)
Symbol
Parameter
IDD
Supply current
VOL
INT, SDA output low
voltage
ILEAK
Leakage current, SDA,
SCL, INT pins
VIH
SCL, SDA input high
voltage
VIL
SCL, SDA input low
voltage
Conditions
Min Typ Max Units
Active
235
330
Wait state
60
μA
Sleep state - no I²C activity
1.0
10
3 mA sink current
0
6 mA sink current
0
0.4
V
0.6
-5
5
μA
TCS34001, TCS34005
TCS34003, TCS34007
TCS34001, TCS34005
TCS34003, TCS34007
0.7 VDD
1.26
V
0.3 VDD
V
0.54
ams Datasheet
[v1-01] 2016-Apr-13
Page 5
Document Feedback