English
Language : 

EPM7032AETI44-7N Datasheet, PDF (27/64 Pages) Altera Corporation – Programmable Logic Device Family
MAX 7000A Programmable Logic Device Data Sheet
Figure 9. MAX 7000A AC Test Conditions
Power supply transients can affect AC
measurements. Simultaneous transitions
of multiple outputs should be avoided for
accurate measurement. Threshold tests
must not be performed under AC
conditions. Large-amplitude, fast-ground-
current transients normally occur as the
device outputs discharge the load
capacitances. When these transients flow
through the parasitic inductance between
the device ground pin and the test system
ground, significant reductions in
observable noise immunity can result.
Numbers in brackets are for 2.5-V
outputs. Numbers without brackets are for
3.3-V outputs.
703 Ω
[521 Ω]
Device
Output
586 Ω
[481 Ω]
Device input
rise and fall
times < 2 ns
VCC
To Test
System
C1 (includes jig
capacitance)
Operating
Conditions
Tables 13 through 16 provide information on absolute maximum ratings,
recommended operating conditions, operating conditions, and
capacitance for MAX 7000A devices.
Table 13. MAX 7000A Device Absolute Maximum Ratings Note (1)
Symbol
Parameter
VCC
VI
IOUT
TSTG
TA
TJ
Supply voltage
DC input voltage
DC output current, per pin
Storage temperature
Ambient temperature
Junction temperature
Conditions
With respect to ground (2)
No bias
Under bias
BGA, FineLine BGA, PQFP, and
TQFP packages, under bias
Min Max Unit
–0.5
4.6
V
–2.0
5.75
V
–25
25
mA
–65
150
°C
–65
135
°C
135
°C
Altera Corporation
27