English
Language : 

EP1S10 Datasheet, PDF (182/290 Pages) Altera Corporation – Stratix Device Family Data Sheet
Operating Conditions
Table 4–2. Stratix Device Recommended Operating Conditions (Part 2 of 2)
Symbol
VCCIO
VI
VO
TJ
Parameter
Supply voltage for output
buffers, 3.3-V operation
Supply voltage for output
buffers, 2.5-V operation
Supply voltage for output
buffers, 1.8-V operation
Supply voltage for output
buffers, 1.5-V operation
Input voltage
Output voltage
Operating junction
temperature
Conditions
(4), (5)
Minimum Maximum Unit
3.00 (3.135) 3.60 (3.465) V
(4)
2.375
2.625
V
(4)
1.71
1.89
V
(4)
1.4
1.6
V
(3), (6)
–0.5
0
For commercial use
0
For industrial use
–40
4.0
V
VCCIO
V
85
°C
100
°C
Table 4–3. Stratix Device DC Operating Conditions Note (7) (Part 1 of 2)
Symbol
Parameter
Conditions
Minimum Typical Maximum Unit
II
Input pin leakage VI = VCCIOmax to 0 V (8)
–10
current
IOZ
Tri-stated I/O pin VO = VCCIOmax to 0 V (8)
–10
leakage current
10
μA
10
μA
ICC0
VCC supply current VI = ground, no load, no
mA
(standby) (All
toggling inputs
memory blocks in
power-down mode)
EP1S10. VI = ground, no
load, no toggling inputs
37
mA
EP1S20. VI = ground, no
65
mA
load, no toggling inputs
EP1S25. VI = ground, no
90
mA
load, no toggling inputs
EP1S30. VI = ground, no
114
mA
load, no toggling inputs
EP1S40. VI = ground, no
145
mA
load, no toggling inputs
EP1S60. VI = ground, no
200
mA
load, no toggling inputs
EP1S80. VI = ground, no
277
mA
load, no toggling inputs
4–2
Stratix Device Handbook, Volume 1
Altera Corporation
July 2005