English
Language : 

EPM3032ATC44-10N Datasheet, PDF (15/46 Pages) Altera Corporation – Programmable Logic Device Family
MAX 3000A Programmable Logic Device Family Data Sheet
By combining the pulse and shift times for each of the programming
stages, the program or verify time can be derived as a function of the TCK
frequency, the number of devices, and specific target device(s). Because
different ISP-capable devices have a different number of EEPROM cells,
both the total fixed and total variable times are unique for a single device.
Programming a Single MAX 3000A Device
The time required to program a single MAX 3000A device in-system can
be calculated from the following formula:
tPROG
=
tPPUL
S
E
+
C-----y---c---l---e--P----T----C-----K--
fTCK
where: tPROG
tPPULSE
CyclePTCK
fTCK
= Programming time
= Sum of the fixed times to erase, program, and
verify the EEPROM cells
= Number of TCK cycles to program a device
= TCK frequency
The ISP times for a stand-alone verification of a single MAX 3000A device
can be calculated from the following formula:
tVER
=
tVP
UL
S
E
+
-C----y---c---l--e---V-----T----C----K---
fTCK
where: tVER
= Verify time
tVPULSE = Sum of the fixed times to verify the EEPROM cells
CycleVTCK = Number of TCK cycles to verify a device
Altera Corporation
15