b) Output span voltage adjustment (Register names: SCS, SC)
Adjusts the span voltage.
The magnification factor in this table represents an adjustment factor benchmarked to a VOUT output of
4000mV (@VDD: 5V) as 1 (factor) = 100[%]/100[%].
The output and sensitivity describes the adjustable output voltages with the assumed reference
output (2V@VDD: 3V, 4V@VDD: 5V) when ESC[8:0] = 0 dec.
Address: 02 hex - 03 hex D[8:0]=ESC[8:0]
ESC[8:0]
Magnification
VDD: 3V
Dec Hex
Bin
(Factor)
Output Sens.
(mV) (Factor)
-256 100 100000000 100/164.00 1220 30.488
-255 101 100000001 100/163.75 1221 30.534
:
:
:
:
:
:
-160 160 101100000 100/140.00 1429 35.714
-159 161 101100001 100/139.75 1431 35.778
:
:
:
:
:
:
-41 1D7 111010111 100/110.25 1814 45.351
-40 1D8 111011000 100/110.00 1818 45.455
:
:
:
:
:
:
-2 1FE 111111110 100/100.50 1990 49.751
-1 1FF 111111111 100/100.25 1995 49.875
0 000 000000000 100/100.00 2000 50.000
1 001 000000001 100/99.75 2005 50.125
2 002 000000010 100/99.50 2010 50.251
:
:
:
:
:
:
40 028 000101000 100/90.00
41 029 000101001 100/89.75
2222 55.556
2228 55.710
:
:
:
:
159 09F 010011111 100/60.25
:
:
3320 82.988
160 0A0 010100000 100/60.00
:
:
:
:
254 0FE 011111110 100/36.50
255 0FF 011111111 100/36.25
3333
:
5479
5517
83.333
:
136.99
137.93
VDD: 5V
Output Sens.
(mV) (Factor)
2439 30.488
2443 30.534
:
:
2857 35.714
2862 35.778
:
:
3628 45.351
3636 45.455
:
:
3980 49.751
3990 49.875
4000 50.000
4010 50.125
4020 50.251
:
:
4444 55.556
4457 55.710
:
:
6639 82.988
6667 83.333
:
:
10959 136.99
11034 137.93