English
Language : 

AK8996 Datasheet, PDF (25/74 Pages) Asahi Kasei Microsystems – Pressure Sensor Interface IC
[AK8996/W]
3.2 Self-Diagnostic Circuit in Operation
No. State
Trigger
Operations
00 Start Up
10 ST0
20 PJ0
34 STV4
4 MSR4
14 ST4
15 ST5
20 PJ0
30 STV0
3 MSR
::
CLK=5
CLK=8
CLK=18
CLK=51
CLK=100
CLK=105
CLK=108
CLK=118
:
Analog circuit settling time for stable operation.
Analog reference circuits VREF & IREF start up and
configured output reference voltage is provided at VOUT
pin.
Clock count start
Analog circuit startup
Pressure judge circuit not in operation
SV initial operation (ST not in operation)
VP&VN pin fixed to 1/2*VS; given value output to VOUT
Self-diagnostic circuit operation & idling
Back to normal operation on completing self-diagnosis in
50 CLK.
Analog circuit startup
Pressure judge circuit not in operation
STV initial operation
Output pressure (VP-VN=0V) to VOUT
:(Same as operation after ST3 in 3.1 Normal Operation
Timing)
MS1055-E-02
25