English
Language : 

AK4528 Datasheet, PDF (20/29 Pages) Asahi Kasei Microsystems – HIGH PERFORMANCE 24BIT 96KHZ AUDIO CODEC
ASAHI KASEI
[AK4528]
n Register Definitions
Addr
00H
Register Name
Power Down Control
default
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
0
PWVR PWAD PWDA
0
0
0
0
0
1
1
1
PWDA: DAC power down
0: Power down
1: Power up
Only DAC section is powered down by “0” and then the AOUTs go Hi-Z immediately. The OATTs also go
“00H”. But the contents of all register are not initialized and enabled to write to the registers.
After exiting the power down mode, the OATTs fade in the setting value of the control register (04H &
05H). The analog outputs should be muted externally as some pop noise may occur when entering to and
exiting from this mode.
PWAD: ADC power down
0: Power down
1: Power up
Only ADC section is powered down by “0” and then the SDTO goes “L” immediately. The contents of all
register are not initialized and enabled to write to the registers.
After exiting the power down mode, ADC outputs “0” during first 516 LRCK cycles.
PWVR: Vref power down
0: Power down
1: Power up
All sections are powered down by “0” and then both ADC and DAC do not operate. The contents of all
register are not initialized and enabled to write to the registers. When PWAD and PWDA go “0” and PWVR
goes “1”, only VREF section can be powered up.
Addr
01H
Register Name
Reset Control
default
D7
D6
D5
D4
D3
TE7
TE6
TE5
TE4
0
0
0
0
0
0
D2
D1
D0
0
RSTADN RSTDAN
0
0
0
TE7-4: Test Control Register Enable
Must be fixed to “0000”.
RSTDAN: DAC reset
0: Reset
1: Normal Operation
The internal timing is reset by “0” and then the AOUTs go VCOM voltage immediately. The OATTs also go
“00H”. But the contents of all register are not initialized and enabled to write to the registers. After exiting
the power down mode, the OATTs fade in the setting value of the control register (06H & 07H). The analog
outputs should be muted externally as some pop noise may occur when entering to and exiting from this
mode.
RSTDAN: ADC reset
0: Reset
1: Normal Operation
The internal timing is reset by “0” and then SDTO goes “L” immediately. But the contents of all register are
not initialized and enabled to write to the register.
After exiting the power down mode, ADCs output “0” during first 516 LRCK cycles.
MS0011-E-00
- 20 -
2000/1