English
Language : 

AMIS30623C623BRG Datasheet, PDF (49/61 Pages) ON Semiconductor – Micro-stepping Motor Driver
AMIS−30623
GetOTPparam
This command is provided to the circuit by the LIN master
after a preparing frame (see Preparing frames), to read the
content of an OTP memory segment which address was
specified in the preparation frame.
GetOTPparam corresponds to a LIN in−frame response with 0x3D indirect ID.
1. The master sends a type #7 preparing frame. After the type#7 preparing frame, the master sends a reading frame
type#6 to retrieve the circuit’s in−frame response.
Table 49. GetOTPparam PREPARING FRAME TYPE #7
Byte
0
1
2
3
Content
Identifier
Data 1
Data 2
Checksum
Bit 7
*
1
1
Bit 6
*
Bit 5
0
Structure
Bit 4
Bit 3
Bit 2
ID4
ID3
ID2
CMD[6:0] = 0x02
AD[6:0]
Checksum over data
Bit 1
ID1
Bit 0
ID0
Table 50. GetOTPparam READING FRAME TYPE #6
Byte
Content
Bit 7
0
Identifier
0
1
Data 1
2
Data 2
3
Data 3
4
Data 4
5
Data 5
6
Data 6
7
Data 7
8
Data 8
9
Checksum
Where:
(*) According to parity computation
Bit 6
1
Bit 5
1
Structure
Bit 4
Bit 3
1
1
OTP byte @0x00
OTP byte @0x01
OTP byte @0x02
OTP byte @0x03
OTP byte @0x04
OTP byte @0x05
OTP byte @0x06
OTP byte @0x07
Checksum over data
Bit 2
1
Bit 1
0
Bit 0
1
2.) The master sends a type #8 preparing frame. After the type#8 preparing frame, the master sends a reading frame type#6
to retrieve the circuit’s in−frame response.
Table 51. GetOTPparam PREPARING FRAME TYPE #8
Byte
0
1
2
3
4
5
6
7
8
9
Content
Identifier
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Checksum
Bit 7
0
1
1
Bit 6
0
Bit 5
1
Structure
Bit 4
Bit 3
1
1
AppCMD =80
CMD[6:0] = 0x02
AD[6:0]
Data4[7:0] FF
Data5[7:0] FF
Data6[7:0] FF
Data7[7:0] FF
Data8[7:0] FF
Checksum over data
Bit 2
1
Bit 1
0
Bit 0
0