The circuit will return to normal mode if a valid LIN frame
is received (this valid frame can be addressed to another
slave).
Thermal Shutdown Mode
When thermal shutdown occurs, the circuit performs a
<SoftStop> command and goes to motor shutdown
mode (see Figure 14: State Diagram Temperature
Management).
Temperature Management
The AMISâ30623 monitors temperature by means of two
thresholds and one shutdown level, as illustrated in the state
diagram and illustration of Figure 14: State Diagram
Temperature Management below. The only condition to
reset flags <TW> and <TSD> (respectively thermal warning
and thermal shutdown) is to be at a temperature lower than
Ttw and to get the occurrence of a GetStatus or a
GetFullStatus LIN frame.
Normal Temp.
â<Tinfo> = â00â
â<TW> = â0â
â<TSD> = â0â
T° > Ttw
Thermal warning
â<Tinfo> = â10â
â<TW> = â1â
â<TSD> = â0â
T° > Ttsd
T° < Ttw &
LIN frame:
T° > Ttw
GetStatus or
GetFullStatus
T° < Ttw
Thermal shutdown
â<Tinfo> = â11â
â<TW> = â1â
â<TSD> = â1â
âSoftStop if
motion ongoing
âMotor shutdown
(motion disabled)
T° < Tlow
T° > Tlow
Low Temp.
â<Tinfo> = â01â
â<TW> = â0â
â<TSD> = â0â
Post thermal
warning
â<Tinfo> = â00â
â<TW> = â1â
â<TSD> = â0â
Post thermal
shutdown 2
â<Tinfo> = â00â
â<TW> = â1â
â<TSD> = â1â
âMotor shutdown
(motion disabled)
T° > Ttsd
T° < Ttsd
T° < Ttw
Post thermal
shutdown 1
â<Tinfo> = â10â
â<TW> = â1â
â<TSD> = â1â
âMotor shutdown
(motion disabled)
T° > Ttw
Figure 14. State Diagram Temperature Management