English
Language : 

CN-0294 Datasheet, PDF (3/5 Pages) Analog Devices – Increasing the Number of Outputs from a Clock Source Using Low Jitter LVPECL Fanout Buffers
Circuit Note
Logic Level Measurement
In this example, the Rohde & Schwarz RTO1024 oscilloscope is
used together with two RT-ZS30 active probes to accurately
measure the high speed logic levels.
Install the ADF435x software to PC by doing the following:
1. Connect the EVAL-ADF4351EB1Z to the PC, follow the
hardware driver instructions as per UG-435.
2. Program the ADF4351 PLL as per the screenshot of the
ADF435x software (see Figure 3). In this example, an RF
frequency of 1 GHz is chosen.
CN-0294
3. Using two equal length short SMA cables, connect the
RFOUTA+ and RFOUTA− SMA connectors from the EVAL-
ADF4351EB1Z board to the CLK0/CLK0 SMA connectors
of the ADCLK948/PCBZ board.
4. Connect the differential output OUT2/OUT2 of the
ADCLK948/PCBZ to the high speed oscilloscope. See
Figure 4 for typical waveforms for a 1 GHz output.
Figure 3. ADF4351 Software Settings
Figure 4. ADCLK948 Oscilloscope Output for 1 GHz Logic Signal, Horizontal Axis: 200 ps/DIV, Vertical Axis: 200 mV/DIV
Rev. 0 | Page 3 of 5