SAVING FILES
The software can save the current captured data for future
analysis. The software can capture the current plot images and
the current device configuration, as well as the raw waveform
data, histogram data, and ac spectrum data.
Saving Data
To save data, go to the File menu and click Save Data. This
action saves the raw data captured as seen in the Waveform tab
in TSV format.
OPENING FILES
Loading Captured Data
The software can load previously captured data for analysis.
Go to the File menu, click Load Data, and select waveform data
previously saved in TSV format. The waveform data is a raw
data capture that rebuilds the histogram and ac spectrum
analyses upon being loaded into the evaluation platform.
Figure 18. Save As Data Dialog Box
Saving Plot Images
To save plot images, go to the desired analysis tab, click the File
menu, and then click Save As Picture.
The images are saved in JPEG format and do not contain any
raw data information. Plots saved as images cannot be loaded
back into the evaluation environment.
Figure 19. Open File Dialog Box
Figure 20. Save As Picture Image Dialog Box