English
Language : 

EVAL-AD7902SDZ Datasheet, PDF (10/32 Pages) Analog Devices – On-board reference
UG-608
LINK CONFIGURATION OPTIONS
Care should be taken before applying power and signals to the
evaluation board to ensure that all link positions are as required
by the operating mode. There are two modes in which to operate
the evaluation board. The evaluation board can be operated in
SDP controlled mode to be used with the SDP board, or the
evaluation board can be used in standalone mode.
EVAL-AD7902SDZ User Guide
When operating in SDP controlled mode, ensure that VIO is
3.3 V. Operating with a VIO greater than 3.3 V in SDP controlled
mode may damage the SDP board.
The Setting column of Table 3 shows the default positions in which
the links are set when the evaluation board is packaged. When
the board is shipped, it is assumed that you are going to operate
the evaluation board with the SDP board (SDP controlled mode).
Table 3. Solder Links—Factory Default Settings
Link
Setting
Function
SL1
A
+VS
SL2
A
−VS
SL3
A
−VS
SL4
A
+VS
SL5
B
Analog input
SL6
B
Analog input
LK1
A
+VS
LK2
A
−VS
LK3
A
V_SDP
LK4
A
VREF
LK5
A
VDD for ADC
LK6
Not applicable
Not applicable
LK7
Not applicable
Not applicable
LK8
A
ADC2 input
LK9
A
ADC2 input
LK10
A
U17 input
LK11
A
U17 input
LK12
A
ADC2 input
Comment
Change to B if using bench supplies.
Change to B if using bench supplies.
Change to B if using bench supplies.
Change to B if using bench supplies.
Do not alter.
Do not alter.
Change to B if using bench supplies.
Change to B if using bench supplies.
Change to B if using bench supplies.
Change to B if using bench supplies.
Change to B if using bench supplies.
Do not place
Do not place
Do not alter.
Change to B if using ADC1 input.
Change to B if U17 needs to be bypassed.
Change to B if U17 needs to be bypassed.
Do not alter.
Rev. 0 | Page 10 of 32