English
Language : 

RTAX-S Datasheet, PDF (20/170 Pages) Actel Corporation – RTAX-S/SL RadTolerant FPGAs
RTAX-S/SL RadTolerant FPGAs
Operating Conditions
Absolute Maximum Conditions
Stresses beyond those listed in Table 2-2 may cause permanent damage to the device. Exposure to Absolute Maximum
rated conditions for extended periods may affect device reliability. Devices should not be operated outside the
recommended operating conditions in Table 2-3.
Table 2-2 • Absolute Maximum Ratings
Symbol
Parameter
Limits
Units
VCCA
AC Core Supply Voltage1
–0.3 to 1.8
V
VCCA
DC Core Supply Voltage
–0.3 to 1.7
V
VCCI
DC I/O Supply Voltage
–0.3 to 3.75
V
VREF
DC I/O Reference Voltage
–0.3 to 3.75
V
VI
Input Voltage
–0.5 to 3.75
V
VO
Output Voltage
–0.5 to 3.75
V
TSTG
Storage Temperature
–60 to +150
°C
VCCDA2
Supply Voltage for Differential I/Os
–0.3 to 3.75
V
Notes:
1. The AC transient VCCA limit is for radiation-induced transients less than 10 µs duration and not intended for repetitive use. Core
voltage spikes from a single event transient will not negatively affect the reliability of the device if, for this non-repetitive event, the
transient does not exceed 1.8 V at any time and the total time that the transient exceeds 1.575 V does not exceed 10 µs in
duration.
2. VCCDA must be greater than or equal to the highest VCCI voltage
Table 2-3 • RTAX-S/SL Recommended Operating Conditions
Parameter Range
Ambient Temperature (TA)1
1.5 V Core Supply Voltage
Military
–55 to +125
1.425 to 1.575
Units
°C
V
1.5 V I/O Supply Voltage
1.425 to 1.575
V
1.8 V I/O Supply Voltage
1.71 to 1.89
V
2.5 V I/O Supply Voltage
2.375 to 2.625
V
3.3 V I/O Supply Voltage
3.0 to 3.6
V
2.5 V VCCDA I/O Supply Voltage (no differential I/O used)
3.3 V VCCDA I/O Supply Voltage (differential or voltage-referenced I/O used)2
3.3 V VPUMP Supply Voltage
Notes:
2.375 to 2.625
V
3.0 to 3.6
V
3.0 to 3.6
V
1. Ambient temperature (TA) is used for commercial and industrial grades; case temperature (TC) is used for military grades.
2. Please see "VCCDA Supply Voltage" on page 2-11 more detail.
3. Tj (max) = 125ºC.
Overshoot/Undershoot Limits
For AC signals, the input signal may undershoot during
transitions to –1.0 V for no longer than 10% of the
period or 11 ns (whichever is smaller). Current during the
transition must not exceed 95 mA.
For AC signals, the input signal may overshoot during
transitions to VCCI + 1.0 V for no longer than 10% of the
period or 11 ns (whichever is smaller). Current during the
transition must not exceed 95 mA.
Note: The above specification does not apply to the PCI
standard. The RTAX-S/SL PCI I/Os are compliant to the PCI
standard including the PCI overshoot/undershoot
specifications.
2-2