Z8FS021 Datasheet, PDF (63/68 Pages) Zilog, Inc. – Select from an assortment of lenses and pyroelectric sensors to best fit your application
ZMOTION® Intrusion Detection
Product Specification
55
Dual Pyroelectric Sensors
In Dual Pyro mode, the second pyroelectric sensor is connected to ANA3. The signal from
VREF to ANA3 is not required. In this design example, the internal VREF is used with
PIR_ASC0 bit 7 set to 0. The user could choose to use an externally generated VREF
source in which case it would be connected to pin 3 and PIR_ASC0 bit 7 would be set to 1.
All other connections remain the same as Single Pyro Mode. See Figure 11.
VDD (3.3V)
1uF
Pyro Electric
Sensor 1
VD D
SI G
47K
GND
V DD (3. 3V )
1uF
Pyr o Electric
Sensor 2
VDD
SI G
47K
GND
Status LED &
WhiteL ight
Detection
470
1 ANA2
2 P B4/A NA7
3 PB5/ VRE F
4 ANA3
5 AV DD
6 VDD
7 PA0/ T0IN/T0OUT/X IN
8 PA 1/T0OUT/X OUT
9 V SS
10 AVS S
11 P A2/DE0
12
P A3/CTS 0
13 P A4/RXD0
14 P A5/T XD0
PB 1/ANA1 28
27
PB 0/ ANA0
P C3/ COUT 26
PC2/A NA 6 25
P C1/ ANA5/CI NN 24
P C0/ ANA4/CINP 23
DBG 22
21
RE SE T/PD0
PC7 20
PC6 19
PA 7/T1OUT 18
PC5 17
PC4 16
PA6/ T1IN/T1OUT 15
Z 8FS021xHH20EG
VDD (3.3V)
10K
10K
Debug Header
1 V CC
2 RES ET
3 GND
4 DBG
5 GND
6 NC
Figure 11. Required Circuit Connections for the Z8FS021xHJ20EG (28-Pin) ZMOTION Intrusion
Detection MCU, Dual Pyro Mode
PS028806-0315
Appendix A. Example Application Schematics