Z8FS021 Datasheet, PDF (60/68 Pages) Zilog, Inc. – Select from an assortment of lenses and pyroelectric sensors to best fit your application
ZMOTION® Intrusion Detection
Product Specification
52
Dual Pyroelectric Sensors
In Dual Pyro mode, the second pyroelectric sensor is connected to ANA3. The signal from
VREF to ANA3 is not required. In this design example, the internal VREF is used with
PIR_ASC0 bit 7 set to '0'. The user could choose to use an externally generated VREF
source in which case it would be connected to pin 18 and PIR_ASC0 bit 7 would be set to
'1'. All other connections remain the same as Single Pyro Mode. See Figure 9.
VDD (3.3V)
1uF
VDD (3.3V)
1uF
Pyro Electric
Sensor 1
VDD
SIG
GND
47 K
VDD (3.3V)
1uF
Pyro Electric
Sensor 2
VDD
SIG
47 K
GND
470
Status LED &
White Light
Detection
1 PB1/ANA1
PB0/ANA0 20
2 ANA2
PC3 /COUT 19
3 ANA3
PC2/ANA6/LED /VREF 18
4 VDD
PC1/ANA5/CINN 17
5 PA0/T0IN /T0 OUT/XIN PC0 /ANA4 /CINP 16
6 PA 1/T0OUT/XOUT
DBG 15
7 VSS
14
R ESET/PD0
8 PA2/D E0
PA7/T1 OUT 13
9 PA 3/CTS0
PA6/T1IN/T1 OUT 12
10 PA4/RXD0
PA5 /TXD0 11
Z8FS021xHH20EG
VD D(3.3V)
10K
10K
Debug Header
1 VCC
2 RESET
3 GND
4 DBG
5 GND
6 NC
Figure 9. Example Circuit with the Z8FS021xHH20EG (20-Pin) ZMOTION Intrusion Detection MCU,
Dual Pyro Mode
PS028806-0315
Appendix A. Example Application Schematics