38
Caution: Writing a 1 is the only way to reset the Terminal Count
status condition. Therefore, you must reset this bit before
using/enabling the counter/timers.
The first clock of T8 might not exhibit complete clock width
and can occur anytime when enabled.
Note: Care must be taken when using the OR or AND commands to
manipulate CTR0, bit 5 and CTR1, bits 0 and 1 (demodulation
mode). These instructions use a Read-Modify-Write sequence
in which the current status from the CTR0 and CTR1 registers
is ORed or ANDed with the designated value and then written
back into the registers.
For example, when the status of bit 5 is 1, a timer reset condition occurs.
T8 Clock
This bit defines the frequency of the input signal to T8.
Capture_INT_Mask
Set this bit to allow an interrupt when data is captured into either LO8 or HI8 upon
a positive or negative edge detection in demodulation mode.
Counter_INT_Mask
Set this bit to allow an interrupt when T8 has a time-out.
P34_Out
This bit defines whether P34 is used as a normal output pin or the T8 output.