English
Language : 

Z86L33 Datasheet, PDF (16/16 Pages) Zilog, Inc. – CMOS Z8 CONSUMER CONTROLLER PROCESSOR
AC ELECTRICAL CHARACTERISTICS
Handshake Timing Table
No Symbol
Parameter
T=
A
0°C
to
+70°C
V
8 MHz
CC
Note [1] Min Max
1 TsDI(DAV)
2 ThDI(RDY)
Data In Setup Time
Data In Hold Time
2.0V 0
3.9V 0
2.0V 0
3.9V 0
3 TwDAV
Data Available Width
2.0V
3.9V
4 TdDAVI(RDY) DAV Fall to RDY Fall Delay 2.0V
3.9V
155
110
0
0
5 TdDAVId(RDY) DAV Out to DAV Fall Delay 2.0V
3.9V
6 RDY0d(DAV) RDY Rise to DAV Fall Delay 2.0V
3.9V
120
80
0
0
7 TdD0(DAV) Data Out to DAV Fall Delay 2.0V 63
3.9V 63
8 TdDAV0(RDY) DAV Fall to RDY Fall Delay 2.0V 0
3.9V 0
9 TdRDY0(DAV) RDY Fall to DAV Rise Delay 2.0V
3.9V
10 TwRDY
RDY Width
2.0V
3.9V
11 TdRDY0d(DAV) RDY Rise to DAV Fall Delay 2.0V
3.9V
160
115
110
80
110
80
Notes:
[1] Timing Reference uses 0.7 VCC for a logic 1 and 0.2 VCC for a logic 0.
[2] VCC = 2.0V to 3.9V.
Direction
Data
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
Z86L33/L43
CP96LVO1501
© 1996 by Zilog, Inc. All rights reserved. No part of this document
may be copied or reproduced in any form or by any means
without the prior written consent of Zilog, Inc. The information in
this document is subject to change without notice. Devices sold
by Zilog, Inc. are covered by warranty and patent indemnification
provisions appearing in Zilog, Inc. Terms and Conditions of Sale
only. Zilog, Inc. makes no warranty, express, statutory, implied or
by description, regarding the information set forth herein or
regarding the freedom of the described devices from intellectual
property infringement. Zilog, Inc. makes no warranty of mer-
chantability or fitness for any purpose. Zilog, Inc. shall not be
responsible for any errors that may appear in this document.
Zilog, Inc. makes no commitment to update or keep current the
information contained in this document.
Zilog’s products are not authorized for use as critical compo-
nents in life support devices or systems unless a specific written
agreement pertaining to such intended use is executed between
the customer and Zilog prior to use. Life support devices or
systems are those which are intended for surgical implantation
into the body, or which sustains life whose failure to perform,
when properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result in
significant injury to the user.
Zilog, Inc. 210 East Hacienda Ave.
Campbell, CA 95008-6600
Telephone (408) 370-8000
FAX 408 370-8056
Internet: http://www.zilog.com
16