English
Language : 

XC6VLX130T-1FF484I Datasheet, PDF (6/65 Pages) Xilinx, Inc – DC and Switching Characteristics
Virtex-6 FPGA Data Sheet: DC and Switching Characteristics
Table 4: Typical Quiescent Supply Current (Cont’d)
Symbol
Description
ICCAUXQ Quiescent VCCAUX
supply current
Device
XC6VLX75T
XC6VLX130T
XC6VLX195T
XC6VLX240T
XC6VLX365T
XC6VLX550T(3)
XC6VLX760(3)
XC6VSX315T
XC6VSX475T(3)
XC6VHX250T
XC6VHX255T
XC6VHX380T(4)
XC6VHX565T(5)
XQ6VLX130T(6)
XQ6VLX240T(6)
XQ6VLX550T(7)
XQ6VSX315T(6)
XQ6VSX475T(7)
-3 (C)
45
75
113
135
191
N/A
N/A
186
N/A
152
152
227
N/A
N/A
N/A
N/A
N/A
N/A
Speed and Temperature Grade
-2 (C, E, & I) -1 (C & I) -1 (I & M)(2) -1L (C)
45
45
N/A
45
75
75
N/A
75
113
113
N/A
113
135
135
N/A
135
191
191
N/A
191
286
286
N/A
286
387
387
N/A
387
186
186
N/A
186
279
279
N/A
279
152
152
N/A
N/A
152
152
N/A
N/A
227
227
N/A
N/A
315
315
N/A
N/A
75
N/A
75
N/A
135
N/A
135
N/A
N/A
N/A
286
N/A
186
N/A
186
N/A
N/A
N/A
279
N/A
-1L (I)(1) Units
45
mA
75
mA
113
mA
135
mA
191
mA
286
mA
387
mA
186
mA
279
mA
N/A
mA
N/A
mA
N/A
mA
N/A
mA
75
mA
135
mA
286
mA
186
mA
279
mA
Notes:
1. Typical values are specified at nominal voltage, 85°C junction temperatures (Tj). -1 and -2 industrial (I) grade devices have the same typical
values as commercial (C) grade devices at 85°C, but higher values at 100°C. Use the XPE tool to calculate 100°C values. -1L industrial
temperature range devices have the values specified in this column.
2. Use the XPE tool to calculate 125°C values for -1M temperature range devices.
3. The -2E extended temperature range (Tj = 0°C to +100°C) is only available in these devices. The -2I temperature range (Tj = –40°C to
+100°C) is available for all other devices except the XC6VHX565T.
4. The XC6VHX380T is available with both -2E and -2I temperature ranges.
5. The XC6VHX565T is only available in the following temperature ranges: -1C, -1I, -2C, and -2E.
6. The XQ6VLX130T, XQ6VLX240T, and XQ6VSX315T are available in -2I, -1I, -1M, and -1LI temperature ranges.
7. The XQ6VLX550T and the XQ6VSX475T are only available in -1I and -1LI temperature ranges.
8. Typical values are for blank configured devices with no output current loads, no active input pull-up resistors, all I/O pins are 3-state and
floating.
9. If DCI or differential signaling is used, more accurate quiescent current estimates can be obtained by using the XPE or XPower Analyzer
(XPA) tools.
Power-On Power Supply Requirements
Xilinx FPGAs require a certain amount of supply current during power-on to insure proper device initialization. The actual
current consumed depends on the power-on sequence and ramp rate of the power supply.
The recommended power-on sequence for Virtex-6 devices is VCCINT, VCCAUX, and VCCO to meet the power-up current
requirements listed in Table 5. VCCINT can be powered up or down at any time, but power up current specifications can vary
from Table 5. The device will have no physical damage or reliability concerns if VCCINT, VCCAUX, and VCCO sequence cannot
be followed.
If the recommended power-up sequence cannot be followed and the I/Os must remain 3-stated throughout configuration,
then VCCAUX must be powered prior to VCCO or VCCAUX and VCCO must be powered by the same supply. Similarly, for power-
down, the reverse VCCAUX and VCCO sequence is recommended if the I/Os are to remain 3-stated.
DS152 (v3.5) May 17, 2013
www.xilinx.com
Product Specification
6