English
Language : 

X24C02 Datasheet, PDF (9/16 Pages) Xicor Inc. – Serial E2PROM
X24C02
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ................................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature (Soldering, 10 Seconds) ..... 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
70°C
+85°C
+125°C
3838 PGM T09
Supply Voltage
X24C02
X24C02-3.5
X24C02-3
X24C02-2.7
Limits
4.5V to 5.5V
3.5V to 5.5V
3V to 5.5V
2.7 to 5.5V
3838 PGM T10
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified).
Limits
Symbol
Parameter
Min.
Max. Units
Test Conditions
lCC1
lCC2
ISB(1)
ISB(2)
ILI
ILO
VlL(2)
VIH(2)
VOL
Power Supply Current (read)
1
mA SCL = VCC x 0.1/VCC x 0.9 Levels
@ 100 KHz, SDA = Open, All Other
Power Supply Current (write)
2
Inputs = GND or VCC – 0.3V
Standby Current
50
µA SCL = SDA = VCC – 0.3V, All other
Inputs = GND or VCC, VCC = 5.5V
Standby Current
30
µA SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC = 3.3V + 10%
Input Leakage Current
10
µA VIN = GND to VCC
Output Leakage Current
10
µA VOUT = GND to VCC
Input Low Voltage
–1.0 VCC x 0.3 V
Input High Voltage
VCC x 0.7 VCC + 0.5 V
Output Low Voltage
0.4
V IOL = 3 mA
3838 PGM T02
CAPACITANCE TA = 25°C, f = 1 MHz, VCC = 5V
Symbol
Parameter
CI/O(3)
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL, WC)
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
3838 PGM T04
9