3838 PGM T05
A.C. CHARACTERISTICS (Over recommended operating conditions)
DATA INPUT TIMING
OUTPUT
5.0V
1533Ω
100pF
Symbol
Parameter
Min.
Max.
fSCL
SCL Clock Frequency
TI
Noise Suppression Time
Constant at SCL, SDA Inputs
0
100
100
tAA
SCL Low to SDA Data Out Valid
0.3
3.5
tBUF
Time the Bus Must Be Free Before a
4.7
New Transmission Can Start
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
Start Condition Hold Time
Clock Low Period
Clock High Period
Start Condition Setup Time
Data In Hold Time
Data In Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
4.0
4.7
4.0
4.7
0
250
1
300
4.7
300
Bus Timing
tF
tHIGH
tLOW
tR
SCL
tSU:STA
tHD:STA tHD:DAT
tSU:DAT
tSU:STO
SDA IN
3838 FHD F18
Units
KHz
ns
µs
µs
µs
µs
µs
µs
µs
ns
µs
ns
µs
ns
3838 PGM T06
tAA
tDH
tBUF
SDA OUT
3838 FHD F04
POWER-UP TIMING
Symbol
Parameter
Max.
Units
tPUR(4)
Power-up to Read Operation
1
ms
tPUW(4)
Power-up to Write Operation
5
ms
3838 PGM T07
Notes: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters